09-19-2015, 12:10 PM | #1 (permalink) |
Join Date: Apr 15 2005 Location: Jacksonville, FL Age: 54
Posts: 109
Rep Power: 19 | ETS Beds catching fire Ok.....in a week I've had a Starpower 548 and Solaris 442 wiring harness catch fire. Both beds were installed in Sept 2006, never had any issues with either before. The Starpower has considerable fewer hours of use than the Solaris. Incoming voltage is 208v, boosted to 230v....exactly 231.4. The bed is rated for 230. There should be a +/- to handle the fluctuations of the power company. What do you think caused these to burn from the inside of the receptacle? Thanks for the help Pics attached
__________________ www.fourseasonstan.info Last edited by 4SeasonsTan; 09-19-2015 at 12:13 PM. |
09-19-2015, 07:30 PM | #2 (permalink) |
Join Date: Aug 21 2009 Location: IL
Posts: 72
Rep Power: 0 | Re: ETS Beds catching fire I have had 2 beds do this. It is the wiring harness that malfunctions. Tim... bed repair guy at Four Seasons Sales and Service says nothing we have done or not done... It just happened. Faulty wiring when made... maybe? |
09-21-2015, 08:02 AM | #3 (permalink) |
Lamp Geek Join Date: Dec 21 2001 Location: Cleveland, Ohio
Posts: 1,913
Rep Power: 23 | Re: ETS Beds catching fire The bed is about 10 years old, They only rate those beds at 220V, usually there is a warning not to run them higher than 220V. Looks like it burned right at the back of the canopy where it connects to the bench? That open/close motion can cause stress, especially if the wires are rubbing against the wall.
__________________ |
09-21-2015, 09:32 AM | #4 (permalink) |
Team TanTalk Join Date: Nov 23 2004 Location: ITA Member & Berman Supporter!
Posts: 3,136
Rep Power: 25 | Re: ETS Beds catching fire If you need them, I have a brand new complete wiring harnesses for the Starpower 548! My cell is 614-783-5518, my email is Ann.wiggins.noe@gmail.com In terms of the cause - as the others said - could be too high of voltage, could be rubbing, could be age. Check the voltage and make sure nothing is pinching or rubbing as the canopy is lifted up and down before you resume use with new harnesses |
09-21-2015, 10:46 PM | #6 (permalink) |
Join Date: Apr 21 2004 Location: Mass.
Posts: 698
Rep Power: 20 | Re: ETS Beds catching fire What Happen is the Load is running higher when busy and the bed is not cooling down full time, for one also the amp are running high as the wire is not rated to carry the amp load., causing meltdown. |
09-23-2015, 09:26 AM | #8 (permalink) |
Team TanTalk Join Date: Nov 23 2004 Location: ITA Member & Berman Supporter!
Posts: 3,136
Rep Power: 25 | Re: ETS Beds catching fire Check your rear fans as well . The cord/harnesses and wiggle loose somewhat easily - you have to lift the canopy to get to the plugs. Those fans cool the unit. All the above things suggested can all add to an issue like you had |
Bookmarks |
Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
Thread Tools | |
| |
Similar Threads | ||||
Thread | Thread Starter | Forum | Replies | Last Post |
Catching Some Rays | Brandy1 | The Benefits of UV Light | 9 | 10-14-2007 06:42 PM |
Wolff System Technology Fights Fire with Fire! | Mr. Repeat | General Tanning Industry Discussions | 0 | 05-31-2005 12:00 PM |
Wolff System Technology Fights Fire with Fire! | detour | General Tanning Industry Discussions | 0 | 05-03-2004 03:52 PM |