Tanning Equipment From Low pressure to High pressure tanning equipment. |
| LinkBack | Thread Tools |
12-17-2005, 04:03 PM | #1 (permalink) |
Join Date: Dec 17 2005
Posts: 2
Rep Power: 0 | T-Max3a Hi I am a new owner of a tanning bed with a T-max3A timer. I bought it from a salon that was going out of business. I have used this bed in the past. My problem is that when I got it home and ran the 220 and set it all up, I can't get the bed to turn on. When I plug in the timer, I get a read of 7.1 then 0. The down arrow works but not the Start/stop or the up arrow. Is it something I missed or do I need a new tmer? |
12-17-2005, 06:15 PM | #2 (permalink) |
Join Date: Nov 30 2000 Location: Ontario Age: 61
Posts: 38,594
Rep Power: 107 | Re: T-Max3a Hmmmmm? Not sure, and I will have to search a bit, but perhaps the timers has been "programed" to run with a TMax Manager............ Check this link to see if you can solve it: www.appdig.com |
12-18-2005, 08:54 AM | #4 (permalink) |
Join Date: Feb 22 2004
Posts: 18
Rep Power: 0 | Re: T-Max3a R U sure the bed works? and was electrically wired correctly? To check this unplug the 3A. Shut off power to bed at electrical service box. Connect with wirenut, The 2 wires that go to the contact part of the back of the board of the 3A(not the 2 wires that got to plug of 3a). Turn breaker for bed back on. Bed should run perfectly,without a timer. CAUTION: do not use your bed like this, someone will get seriously hurt!!!! If bed works, timer issue. If bed does not work, bed issue. Good Luck |
12-18-2005, 02:43 PM | #5 (permalink) |
Join Date: Nov 30 2000 Location: Ontario Age: 61
Posts: 38,594
Rep Power: 107 | Re: T-Max3a If the unit was used with a remote hook-up, it's on-board timer was by-passed. Best to find out. Even though it was the only unit in the shop, it may have been linked to another 3a. |
12-21-2005, 03:55 PM | #6 (permalink) |
Join Date: Feb 22 2003 Location: Michigan Age: 59
Posts: 1,389
Rep Power: 25 | Re: T-Max3a You need to change the T-max to stand alone. I will need to check on which parameter to change, I haven't worked with them in some time. You can also go to www.appdig.com and down load the manual for the t-max timer. This of course if you bed is hooked up correctly and the power is ran correctley. If the unit worked prior to you moving it, I doubt there is a problem with the unit. The 3A will just need the parameter changed. PM if you need more help. |