I am just thinking outloud here. I know this is probably a very dumb question but here goes...

If you have single phase electrical are there any adapters, so to speak, that you could use to hook up a three phase tanning unit?
BooBop is offline   Reply With Quote
Old 12-31-2002, 09:33 AM   #2 (permalink)
 
Join Date: Dec 22 2002
Posts: 3
Rep Power: 0 wpgtanning is on a distinguished road
Hello Mitzi, I am not a electrician but this is what I know. 3 phase power can be switched to single phase power. But single phase power can't be brought up to three phase power. You have to have 3 phase sevice coming in to your salon to have it.
wpgtanning is offline   Reply With Quote
Old 12-31-2002, 09:37 AM   #3 (permalink)
I love Derf!!
 
BooBop's Avatar
 
Join Date: Apr 5 2001
Age: 66
Posts: 7,766
Rep Power: 28 BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of
I agree, but I was wondering why or if an adapter could be possible. LOL I know I am stretching here. Just curious.
BooBop is offline   Reply With Quote
Old 12-31-2002, 09:53 AM   #4 (permalink)
 
Join Date: May 27 2001
Posts: 204
Rep Power: 23 lampman is on a distinguished road
There is a device called a phase converter that will convert single phase to 3 phase.We have used them to power electric morors but have not tried them in a tanning bed.They look like a motor.
lampman is offline   Reply With Quote
Old 12-31-2002, 10:54 AM   #5 (permalink)
 
Join Date: Aug 16 2002
Location: Chicago IL
Posts: 41
Rep Power: 0 Philips is on a distinguished road
Lampman is correct, what you need is a single phase motor driver connected by shaft to a 3 phase generator. Would be pretty big and not extremely efficient. There are no radio shack 3 phase converters.
Philips is offline   Reply With Quote
Old 12-31-2002, 02:31 PM   #6 (permalink)
I love Derf!!
 
BooBop's Avatar
 
Join Date: Apr 5 2001
Age: 66
Posts: 7,766
Rep Power: 28 BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of BooBop has much to be proud of
There are no radio shack 3 phase converters.
BooBop is offline   Reply With Quote
Old 01-02-2003, 12:18 PM   #7 (permalink)
 
Join Date: May 2 2002
Location: 2621 W Main Suite 9
Posts: 616
Rep Power: 22 bsmart will become famous soon enough
In our business we call these motor-generators. They are large, expensive, inefficient, and make a lot of noise. It would NOT be a practical way to power a tanning bed.
bsmart is offline   Reply With Quote
Old 01-04-2003, 06:37 PM   #8 (permalink)
Guest
 
Join Date: Apr 29 2001
Location: Stewartsville, NJ
Age: 55
Posts: 3,121
Rep Power: 0 Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute Brian Oshman has a reputation beyond repute
Phase converters do not generate clean power and are not recommended to power tanning EQ. All the parts in the bed are single phase. They are just broken up over three poles to balance the larger load. The bed can be re-wired to run on single phase. Some have jumpers internally to do this easily. Others require a little more thought. All beds can be converted either way.
Brian Oshman is offline   Reply With Quote
Reply

Bookmarks



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Here is a really dumb question mikeytan General Tanning Industry Discussions 4 09-03-2005 05:24 PM
(Dumb) upgrade question! lilponygirl Tanning Lotion Buzz 1 04-20-2005 06:17 PM
A dumb question abbronzatura New To The Tanning Business 4 08-29-2003 04:03 PM
Dumb Question BooBop Tanning Salon Management 7 09-22-2002 08:59 PM


All times are GMT -5. The time now is 07:52 PM.


Powered by vBulletin® Version 3.7.2
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
LinkBacks Enabled by vBSEO 3.1.0
Copyright 2009 - tanTALK.com

click here for advertising info!