Question about 240 wiring to alisun provision 41 Hello all, I have a bed that came from a very good friends salon. It worked great now when I get it home I try to wire my main line in and am confused. I have black, white and green wires. I have my recepticle wired as 2 hot legs with no neutral. My question is, I have 2 hots with only 1 line in block to wire 2 hots to. If I connect both legs to one terminal it will trip breaker. I wasn't there when bed was taken down so I didn't see how it was wired. If anyone can help it would be great. If you need more info I have tried all I know but will answer if I can. Thanks in advance |
Re: Question about 240 wiring to alisun provision 41 Any help please? I've called 2 repair guys and an electrician and sent a few emails and nobody responds. I need to get this bed going asap. All I need to know is how I get 240 to the bed. I have it at the recepticle but not sure how to wire the 2 hot legs to the beds main line in block. If I wire them both to the block it trips the breaker. Please any suggestions? Thanks |
Re: Question about 240 wiring to alisun provision 41 Nevermind I figured it out. I guess since I'm a newbie nobody wanted to help me. It was an easy fix and exactly what I thought I needed to do just wanted to make sure before I wired it up |
Re: Question about 240 wiring to alisun provision 41 Take a chill pill. People are working ya know. Someone would have been around to help ya out. But, since you're all set, thread closed. Have a nice day! :D |