Prosun Luxura 40/3 Help.

In my earlier post I mentioned an overtemp 3 error. I fixed that but now standby shows in my readout but the bed still won't start. The bed does not have an external timer. Bought it used. Had the circuit boards repaired, still wouldn't start. Called Prosun and we finally got it working but I had to move a switch on the circuit board to the right then set the time on the timer and then turn the swith back left and then push start and the bed worked normally. Now standby shows as it did when I first moved the switch but nothing I do gets the bed started.
Masterdragon is offline   Reply With Quote
Old 05-07-2008, 07:44 PM   #2 (permalink)
 
Join Date: Aug 12 2002
Location: Michigan
Age: 44
Posts: 277
Rep Power: 6 tanfixr will become famous soon enoughtanfixr will become famous soon enough
Re: Prosun Luxura 40/3 Help.

Which two wires are you jumpering for the remote timer control? Even though the bed didn't come with an external timer, it would have been hooked up to one. It's the round plug on the foot end of the bed behind the vent tubing.
tanfixr is online now   Reply With Quote
Old 05-08-2008, 07:54 AM   #3 (permalink)
 
Join Date: Aug 17 2005
Posts: 8
Rep Power: 0 Masterdragon is on a distinguished road
Re: Prosun Luxura 40/3 Help.

I am familiar with that but now there is no jumper.
Masterdragon is offline   Reply With Quote
Old 05-08-2008, 08:28 AM   #4 (permalink)
 
Join Date: Aug 12 2002
Location: Michigan
Age: 44
Posts: 277
Rep Power: 6 tanfixr will become famous soon enoughtanfixr will become famous soon enough
Re: Prosun Luxura 40/3 Help.

Call whoever you bought the bed from and tell them they sold you an incomplete bed. You need that remote timer plug or it will never work.
tanfixr is online now   Reply With Quote
Old 05-08-2008, 05:39 PM   #5 (permalink)
 
Join Date: Aug 17 2005
Posts: 8
Rep Power: 0 Masterdragon is on a distinguished road
Re: Prosun Luxura 40/3 Help.

We got ripped off. Tried contacting them but to no avail. What do I need to fix it? I may be misunderstanding what you mean by Jumper. Is it just a wire that connects to two terminals on the side where the remote wiring is? There is remote wiring coming out of the bed. They just cut the wires on the outside where they go into the bed.
Masterdragon is offline   Reply With Quote
Old 05-08-2008, 05:52 PM   #6 (permalink)
 
Join Date: Aug 12 2002
Location: Michigan
Age: 44
Posts: 277
Rep Power: 6 tanfixr will become famous soon enoughtanfixr will become famous soon enough
Re: Prosun Luxura 40/3 Help.

At the foot end of the bed behind the exhaust vent, there's a 4 pin round female connector. Plugged into that should be a 4 pin plug with two wires coming out of it.

If that is the case, and is what you're talking about when you say they cut the wires, then tie those two wires together and your bed should work.

If it does work, then those are the wires that go to your Tmax 3A, or whatever room control you are using.
tanfixr is online now   Reply With Quote
Old 05-09-2008, 05:37 PM   #7 (permalink)
 
Join Date: Aug 17 2005
Posts: 8
Rep Power: 0 Masterdragon is on a distinguished road
Re: Prosun Luxura 40/3 Help.

The bed does have the remote plug. The wires were not hooked up. I jumpered the two wires which corresponded to the two coming out of the bed which would connect to the remote timer (Brown & Black). Unplugged the unit and then plugged it back in. Now my timer readout says - TIJD 20 MIN 3* - That's Tee EYE Jay Dee. But, nothing I do starts the bed. I have pushed the small reset button on the circuit board also nothing. There is a small switch next to the reset button which we used to have to move in order to get the timer to work. Then we would switch it to the opposite side and then we could push start and the bed would work. But now that doesn't work.
Masterdragon is offline   Reply With Quote
Old 05-09-2008, 07:09 PM   #8 (permalink)
 
Join Date: Aug 12 2002
Location: Michigan
Age: 44
Posts: 277
Rep Power: 6 tanfixr will become famous soon enoughtanfixr will become famous soon enough
Re: Prosun Luxura 40/3 Help.

Hook those two wires up to a Tmax 3A, or equivalent timer. Power the bed up without the remote circuit activated, then try it. Your language parameter may need to be set. I assume you are hitting the start button too. Does your version have a triac board or a relay board? If you have a triac board, there should be a bank of LEDs lit up when the bed is turned on, and at least one or two when it is off, I think.

Prosun should be able to walk you through this.
tanfixr is online now   Reply With Quote
Reply

Bookmarks
-->



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Looking for Manual for prosun luxura 40/3 vtcg01 For Sale 0 10-17-2005 11:10 PM
Upgrade Bed for Sale - Prosun Luxura 48/8 nikko For Sale 3 09-16-2004 10:58 PM
1995, 1996, 1997 PROSUN LUXURA FOR SALE Keith M For Sale 1 06-03-2004 10:49 AM
ProSun Luxura 102 VHR For Sale theultimatetan For Sale 0 02-12-2004 09:42 AM


All times are GMT -5. The time now is 04:08 PM.


Powered by vBulletin® Version 3.7.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
LinkBacks Enabled by vBSEO 3.1.0
Copyright 2008 Applehat Studios